THHW-2
Bare Copper
Class K (665/30)
.060"
.515"
2 AWG
1
1 lb
190*
170*
-40°F to 221°F (-40°C to 105°C)
600V
*Ampacities of 600V and 1000V 105°C AWM wires in air. Ampacities based on single conductor in free air, 30°C or 40°C ambient temperature as specified, 105°C conductor temperature, per NEC table 310-17 (adjusted for 105°C). Free air ratings assume a one-cable-diameter space between adjacent conductors.
THHW/TEW/MTW/AWM/BC-5W2/SAE TYPE SGT
Multi Listed Flexible Wire
2 AWG
Legend: E312440 2 AWG (33.62mm2) 600 VOLT (UL) TYPE MTW VW-1 OR THHW OR BOAT CABLE BC-5W2 OR AWM STYLES 1232/1284/1338/10269 . . . CSA 234608 TEW 105°C 600V FT1 OR AWM I A/B 600 VOLT 105°C 600V FT1 . . . FOR SAE TYPE SGT
Polar Wire combines finely stranded annealed copper conductors with an extra-flexible, fire retardant PVC jacket for a multipurpose flexible wire that handles better, reduces installation effort, and performs to the highest standards
Single Conductor Multi Listed Flexible Wire is a Class K flexing service wire made with 30 AWG fine conductor stranding for superior flexibility. Constructed of soft annealed bare copper (NO ALUMINUM!) to ASTM Specification B172. Insulated with an extra-flexible extruded, high dielectric PVC jacket that resists abrasion, oils, acids, heat, flame, and moisture, and performs reliably in severe cold temperatures and high heat conditions.
THHW/TEW/MTW/AWM/BC-5W2/SAE TYPE SGT Multi Listed Flexible Wire holds multiple ratings and certifications:
![]()
Multi Listed Flexible Wire (THHW)
Features:
Applications:
Industry Approvals:
![]()
-40°C to 105°C
Construction Specifications:
Class K Finely Stranded Multi Listed Flexible Wire
*Available by special order, minimums may apply
**The ampacities provided are for informational purposes only. Acceptance of these values by any governing body is the responsibility of the end user. Ampacities are based on a single conductor, in free air, at 30°C ambient air temperature. 105°C ampacities adapted from ICEA P-54-440/NEMA WC51-1986 R1991)